![]() The two outside microphones are not recognized by the CTS system.Ĭhange the Second Row Capacity setting from 8 to 12. The second row was configured for a "reduced configuration" second row that seats eight people rather than 12. Orange question mark appears in the Administration interface Troubleshooting > Microphones page for the two outside microphones of the second row table. Contact Cisco technical support if you are certain that the cabling is correct and power is applied to the system, but no sound registers on the microphone.Ĭisco Unified CM Troubleshooting-CTS 32x0 only. If your system supports it, run the microphone calibration procedure in the "Testing Microphones" section of theĬisco TelePresence System Administration Guide.Ĩ. Lightly tap the microphone to see if sound registers.ħ. An unlit light indicates that the microphone is not plugged in.Ħ. Check that the mute light on each microphone is lit. Verify that the microphone plug is firmly seated in the correct connector on the primary codec.ĥ. Verify that the system is plugged in and power is on.Ĥ. Confirm the laptop is not open and in-between the user and the microphoneģ.